SIKA – Oval gear flow meter Type VO…VP

Possible areas of application

SIKA oval gear meters were developed for volume and flow measurement of liquids, and are used in applications including:

  • Lubricant monitoring
  • Food, beverages and tobacco production

Description

  • Positive displacement meter for volumetric flow rate or total flow measurement
  • No inlet or outlet section required
  • High-quality construction for long service life and high reliability
  • Long-term stability
  • High measurement accuracy and repeatability
  • Easy installation


Function
Oval gear meters are displacement-type volume meters that transport defined incremental volumes in individual measuring chambers. The measuring element consists of two high precision toothed oval gears, which are driven by the flow of the medium and mesh with each other. In this way, a defined volume is transported for each rotation of the pair of oval gears. The number of rotations is a measure of the amount of fluid that has passed through the meter. The rotations are detected by a sensor element.

Feature

Measuring range [l/min]
VO 015
VO 06
VO 1
VO 2
VO 5
VO 10
0.03…1
0.5…7
0.1…15
1…30
5…60
10…120
Process connection
VO 015
VO 06
VO 1
VO 2
VO 5
VO 10




G 1
G 1
Accuracy*±0.5 % of reading
Repeatability*< 0.05 %
Pressure ratingUp to 40 bar (up to 25 bar with FEP seal)
Temperature range
Standard
-10…70 °C
Allowable Viscosity0.3…350 mPa s
Degree of protection EN 605290.3…350 mPa s
Nominal puls rate [1/l]
VO 015
VO 06
VO 1
VO 2
VO 5
VO 10
3100
333
166
100
40
20

Diterbitkan oleh Rudy Wiratama

rudywinoto.com/wmablog.com/flowmasonic.com

Satu pendapat untuk “SIKA – Oval gear flow meter Type VO…VP

Tinggalkan Balasan

Please log in using one of these methods to post your comment:

Logo WordPress.com

You are commenting using your WordPress.com account. Logout /  Ubah )

Foto Facebook

You are commenting using your Facebook account. Logout /  Ubah )

Connecting to %s

This site uses Akismet to reduce spam. Learn how your comment data is processed.