Baca Juga : |

Specifications
- Pipe Size: 1, 2, or 3-inch full port
- Fittings: 1-inch NPTF, 2 or 3-inch flange clamps with 2 or 3-inch NPTF fitting kit
- Pressure: 150 psi or 10.3 bar working pressure @ 70˚ F
- Operating Temperature Range : Operating: 10˚ to 130˚ F (-12˚ to 54˚ C), Non-operating: -40˚ to 176˚ F (-40˚ to 80˚ C)
- Accuracy: ±1% of reading (between 10% and 100% of maximum flow), ±3% of reading (between cutoff and 10% of maximum flow)
- Flow Range :
- Minimum : 1”: 2.3 GPM (0.145 l/s) 2”: 6 GPM (0.38 l/s) 3”: 14 GPM (0.88 l/s)
- Maximum : 1”: 110 GPM (6.94 l/s) 2”: 300 GPM (18.9 l/s) 3”: 670 GPM (42.3 l/s)
- Materials :
- Body: Glass-filled polypropylene
- Electrodes 316 stainless steel
- Electronics Housing Power coated diecast aluminum
- Display Cover Polyethylene
- Display
- Digits: Rate 6 digits, Total: 8 digits
- Units Rate: Gallons/Minute, Million Gallons/Day, Cubic Feet/Second, Cubic Feet/Minute, Liters/Second, Liters/Minute, Million Liters/Day, Cubic Meters/Minute, Cubic Meters/Hour
- Units Total Acre-Feet, Acre-Inch, Gallons, Gallons x 1000, Cubic Feet, Liters, Mega liters, Cubic Meters, Cubic Meters x 1000
- Security: Cross-drilled screws and tamper-evident seal (optional)
- Power :
- WMP101 : 10–30 Vdc @ 60 mA maximum (15 mA average) Note: Using an unregulated power supply >18 Vdc may damage the meter due to AC line input voltage fluctuation.
- WMP104: 6 – AA 1.5V lithium cells, replaceable. Estimated life is 1 year depending on usage (standard) 2 – C 3.6V lithium batteries, replaceable. Estimated life is 2–4 years depending on usage (extended battery life opt)
- Pulse Output Signal (WMP101 only) Current sinking pulse, optoisolated, 32 Vdc maximum @ 10mA maximum
- Pulse Rate :
- Low Frequency (-PSU) 1 unit/pulse out, the pulse width of 10 ms, depending on unit selection (WMP101 only)
- High Frequency (-HF) 1” 2” 3” Pulse width 1.1 ms, min-max frequency, 3–150 Hz Pulse/Gal 80 30 13 Pulse/Liter 21.14 7.93 3.44
- Empty Pipe Detection: Hardware/software, conductivity based
- Conductivity : >20 micro Siemens/cm
- Environmental: NEMA 3X, IP64
- Electrical Connection (WMP101 only) 5-pin male circular connector, mates to industry-standard cable

Dimensions
Dimensions are shown without the Seametrics WMP Fitting Kit
Installation