VA 409 Cs instrument Flow direction switch for compressed air systems

CS Instrument Thermal Flow Switch Model VA 409

CS Instrument Thermal Flow Switch Model VA 409

VA 409 Flow direction switch for compressed air systems

The thermal flow direction switch VA 409 with direction indication serves for determination of the flow direction of compressed air and gases, especially in closed circular pipelines.

By means of VA 409 with flow direction indication, the flow direction of the compressed air can be determined quickly and safely. Compared with the former mechanical paddle flow switches VA 409 is able to detect even the smallest changes in the flow direction quickly and without any mechanical movement.

The direction information in form of a potential-free contact (normally closed max. 60 VDC, 0.5 A) is transferred to the consumption sensors VA 500/ VA 520 or to a separate building management system (mbs). Two LEDs show the flow direction.

In connection with 2 consumption sensors VA 500/ VA 520 incoming and outflowing compressed air in closed circular pipelines can be measured precisely.

Special features of the flow direction switch VA 409

  • Compact, small design – for use in machines, behind the maintenance unit on the
    final consumers
  • Screw-in thread for easy installation in existing pipelines due to integrated measuring
    bloc , Sizes : ¼”, ½” ¾”, 1″ 1 ¼” , 1 ½” and 2″
  • Integrated flow straighteners (no inlet runs necessary)
  • Integrated display with a presentation of 2 values
    • Flow & Consumption,
    • Speed & Temperature
  • Operation via integrated keyboard
    • Units selection, freely selectable :  m³/h, m³/min, l/min, l/s, kg/h, kg/min, g/s, lb/min, lb/h
      Cfm, m/s,ft/min
  • Digital interfaces
    • Modbus RTU (RS485)
    • Ethernet
    • MBus
  • Analog interfaces
    •  4 – .20mA
    • Pulse output galv.  insulated.
  • Pressure measurement (optional)

Specification

Detection range recognition flow direction
< 0.1 m/s referred to auf 20 °C and 1000 mbar
Measuring principle
calorimetric measurement
Sensor Pt 30/ Pt 700/ Pt 330
Measuring medium Air, gases
Operating temp.
0…50 °C probe tube
-20…70 °C housing
Operating pressure up to 16 bar
Power supply 24 VDC, 40 mA
Power input Max. 80 mA to 24 VDC
Protection class IP 54
EMV acc. to DIN EN 61326
Connection
2 x M12, 5-pole, plug A and
plug B
2 potential-free contacts
2 x U max. 60 VDC, l max 0,5 A (normally closed); on request: Normally open
Housing
Polycarbonate
Probe tube
stainless steel, 1,4301, length 160 mm, Ø 10 mm, safety ring Ø 11.5 mm, longer probes on request
Mounting thread G 1/2“
Diameter housing 65 mm
Flow direction 2 LEDs

 

For more information please contact our Email : Marketing@wmablog.com

Diterbitkan oleh Rudy Wiratama

rudywinoto.com/wmablog.com/flowmasonic.com

Tinggalkan Balasan

Please log in using one of these methods to post your comment:

Logo WordPress.com

You are commenting using your WordPress.com account. Logout /  Ubah )

Foto Facebook

You are commenting using your Facebook account. Logout /  Ubah )

Connecting to %s

This site uses Akismet to reduce spam. Learn how your comment data is processed.