Seametrics BaroSCOUTThe Seametrics BaroSCOUT Smart Sensor is designed to measure barometric pressure, along with temperature. It is an ideal companion to our absolute pressure/level sensors and can be used to adjust their readings for atmospheric pressure.

This industry-standard digital RS485 interface device records up to 50,000 records of pressure, temperature, and time data operates with low power and features easy-to-use Aqua4Plus 2.0 software with powerful features. Constructed with 316 stainless steel, acetal, and Viton®, this sensor provides high-accuracy readings in rugged and corrosive field conditions.

The BaroSCOUT utilizes an extremely rugged and stable piezo-electric media-isolated pressure element combined with a 16-bit analog-to-digital converter. This provides extremely accurate and stable pressure input into the microprocessor on the circuit board that measures the pressure and stores the data in non-volatile memory.

A replaceable 1/2 AA 3.6v lithium battery powers the BaroSCOUT. The unit is programmed using our easy-to-use control software. Once programmed the unit will measure and collect data at the time interval programmed.

While most will use the BaroSCOUT with Seametrics’ Aqua4Plus 2.0 software, it is by no means limited to that software. You can use your own Modbus® RTU software or logging equipment to read measurements via RS485, tying into your existing telemetry and control systems.

Note: The BaroSCOUT is intended for use in the atmosphere—not to be submerged.

Featuresinstallation of seametrics baroscout

  • Measures/Records barometric pressure and temperature
  • Low power — 4-year battery life
  • Replaceable battery
  • Modbus® RTU (RS485)
  • ± 0.05% FS accuracy
  • Small diameter — 0.875” (2.22 cm)
  • 50,000 record non-volatile memory
  • Barometric compensation utility
  • Free new Aqua4Plus 2.0 software

Another Article:

Application

  • Barometrically compensate absolute pressure sensors for level measurement—no desiccant tubes, bellows, or vent tubes needed!
  • Supplement aquifer test data in leaky or confined conditions

 

Specification

General


Length (cabled version) 6.6” (16.7 cm)
Length (cableless version) 5.1” (12.9 cm)
Diameter 0.875” (2.22 cm)
Body Material 316 stainless steel
Wetted Materials 316 stainless steel, acetal,
fluoropolymer
Communication RS485 Modbus®RTU
Direct Modbus Read Output 32-bit IEEE floating-point
Internal Math 32-bit floating-point
Operating Temp. Range -20° C to 60° C
Storage Temp. Range -40° C to 80° C
Regulatory CE Marking

Logging


Memory 50,000 records
Logging Rate 1x per second
Software Complimentary Aqua4Plus 2.0
File Formats .csv / .a4d

Power


Internal Battery One replaceable 1/2 AA 3.6V lithium battery
Expected Battery Life 4 years (depending on use)

Temperature


Element Type Thermistor
Accuracy ± 0.1° C(from -20° C to 60° C)
Resolution 0.01° C
Units Celsius, Fahrenheit, Kelvin

Pressure


Transducer Type Silicon strain gauge
Transducer Material 316 stainless steel
Units PSI, FtH2O, inH2O, cmH2O,mmH2O,
mH2O, inHg, cmHg,mmHg, Bars, mBars, kPa
Accuracy ± 0.008 PSI ( 0.55 mbar) (@ 20° C)
± 0.02 PSI (1.34 mbar)(@ -20° C to 60° C)
Resolution 0.01% FS (typical)

NOTE: Intended for use in the atmosphere—not to be submerged.

For further information please contact : marketing@wmablog.com

 

Diterbitkan oleh Rudy Wiratama

rudywinoto.com/wmablog.com/flowmasonic.com

Tinggalkan Balasan

Please log in using one of these methods to post your comment:

Logo WordPress.com

You are commenting using your WordPress.com account. Logout /  Ubah )

Foto Facebook

You are commenting using your Facebook account. Logout /  Ubah )

Connecting to %s

This site uses Akismet to reduce spam. Learn how your comment data is processed.