Several versions are available including fixed, adjustable, bi-directional and high pressure. In addition a number of process fittings and materials of construction may be supplied to suit the demand of various applications. HP Series Insertion Turbine Flowmeters for Liquids and Gas 4”-72” Pipe Diameters

  Another Article:

Hoffer HP Series Features

  • Low cost.
  • Low pressure drop.
  • Wide flow turndown ranges for both liquids and gases.
  • Outstanding accuracy.
  • Applications from 4″ to 72″ pipe diameters. Specials upon request.
  • Process connection flexibility.
  • May be installed or removed from active line without stopping service.
  • -20 to +400°F standard operating temperature range with Viton Seal.

Applications

  • Precision flow measurement of liquid and gas applications in large diameter pipes at a lower cost than using an in-line flowmeter.

Insertion for Liquids:
Repeatable Flow Range: .25 to 50 FPS
Accuracy: ±1%

Insertion for Gas:
Repeatable Flow Range: 5 to 250 FPS
Accuracy: ±2%

Hoffer HP Series Specifications

SPECIFICATIONS: LIQUIDS
Linear Flow Ranges:

(Examples)

Minimum Usable Flow Ranges:
5 to 50 FPS.

2 to 20 FPS.

1 to 10 FPS.

0.25 FPS with 2″ Rotor.

0.5 FPS with 1½” Rotor.

LINEARITY: ±1% in 10:1 Flow Turndown Ratios.

Any turndown range with a minimum of 1 FPS and maximum of 50 FPS.

 

SPECIFICATIONS: LIQUIDS
Linear Flow Ranges:

(Examples)

Minimum Usable Flow Ranges:
5 to 50 FPS.

2 to 20 FPS.

1 to 10 FPS.

0.25 FPS with 2″ Rotor.

0.5 FPS with 1½” Rotor.

LINEARITY: ±1% in 10:1 Flow Turndown Ratios.

Any turndown range with a minimum of 1 FPS and maximum of 50 FPS.

General Specifications

  • Repeatability : ±.25% Standard.
  • Max. Operating Pressure :
    150 PSI low pressure adjustable model.
    2500 PSI fixed model.**
    2500 PSI high pressure adjustable model.**
    ** (Dependent on process connection and temperature).
  • Bearing Types : Ceramic Hybrid Ball Bearings, Tungsten Cabide and Hard Carbon Composite Sleeve Bearings.
  • Materials : Stem, housing and rotor support are 316 stainless steel. Stem guide materials – brass (standard). Standard seal is Viton, with others available. Rotor – nickel 200, 430 stainless steel, 17.4 stainless steel (standard).
  • Output Signal (Magnetic Coil) :
    Output level – 10 mV RMS minimum.
    Wave shape – sinusoidal.
    DC resistance of sense coil – 2000 OHMS.
    Coil – variable reluctance type.