Brainchild RSC Rail Signal Conditioner

The signal conditioner incorporates two bright easy to read LCD Displays which indicate Process Value (PV) and user-selected parameter. It is powered by an 11-26 or 90-250 VDC /VAC supply. It is fully programmable for Linear Voltage, Linear Current, PT100 and thermocouple types J, K, T, E, B, R, S, N, L, U, P, C, and D input. The input signal is digitized by using an 18-bit A to D converter. Its fast sampling rate allows the signal conditioner to retransmit the signal faster. It can do a maximum of 3 retransmission with one input.

Feature

The new generation of signal conditioner has a lot of unique features.The unique features are listed below.

  • Optional LCD Display
  • High Accuracy 18 Bit A-D Conversion
  • Up to 3 retransmission outputs with 15 Bit resolution
  • Fastest Sampling Rate of 200 msec
  • Universal Input
  • RS-485 Communication
  • Event Input
  • Lockout Protection
  • Bidirectional Menu Navigation
  • SQRT Function for PV
  Another Article:
The Technology of Ultrasonic Flowmeter
Working Principle of Flow Meter
How to Choose a Flow Meter
Models and Types of Flow Meter
Sound Velocity of Material
Principle Working of Coriolis Mass Flow Meter

Specification

Power

  • Power Supply: 90 to 250VAC, 47 to63Hz, 20 to 28 VAC,47-63Hz / 11 to 40 VDC
  • Power Consumption: 10VA, 5W Maximum

Signal Input

TypeThermocouple (J, K, T, E, B, R, S, N, L, U, P, C, D), RTD(PT100(DIN), PT100(JIS)), Current(mA), Voltage(V)
Resolution18 Bits
Sampling Rate5 Times / Second (200msec)
Maximum Rating-2VDC minimum, 12VDC maximum
Input CharacteristicsTypeRangeAccuracy @ 25°CInput ImpedanceJ-120°C  to 1000°C( -184°F to 1,832°F)±2°C2.2 MΩK-200°C to 1370°C (-328°F to 2498°F)±2°C2.2 MΩT-250°C to 400°C ( -418°F to  752°F )±2°C2.2 MΩE-100°C to 900°C( -148°F to 1652°F )±2°C2.2 MΩB0°C to 1820°C( 32°F to  3308°F )±2°C( 200°C to 1800°C )2.2 MΩR0°C to 1767.8°C( 32°F to 3214°F )±2°C2.2 MΩS0°C to 1767.8°C( 32°F to 3214°F )±2°C2.2 MΩN-250°C to 1300°C( -418°F to 2372°F)±2°C2.2 MΩL-200°C to 900°C( -328°F to 1652°F )±2°C2.2 MΩU-200°C to 600°C (-328°F to 1112°F)±2°C2.2 MΩP0°C to 1395°C( 32°F to 2543°F )±2°C2.2 MΩC0°C to 2300°C( 32°F to 4172°F )±2°C2.2 MΩD0°C to 2300°C( 32°F to 4172°F )±2°C2.2 MΩPT100(DIN)-200°C to 850°C( -328°F to 1562°F )±0.4°C1.3KΩPT100(JIS)-200°C to 600°C( -328°F to 1112°F )±0.4°C1.3KΩmA-3mA  to 27mA±0.05%2.5ΩVDC-1.3VDC to 11.5VDC±0.05%1.5MΩ
Temperature Effect1.5µV /°C for all inputs except mA input, 3.0µV /°C for mA
Sensor Lead Resistance EffectThermocouple: 0.2 µV /Ω; 3-wire RTD: 2.6°C /Ω of Difference of Resistance of two leads
2-wire RTD: 2.6°C /Ω of Sum of Resistance of two leads
Burn-out Current200nA
Common Mode Rejection Ratio(CMRR)120 dB
Normal Mode Rejection Ratio (NMRR)55dB
Sensor Break DetectionSensor open for Thermocouple and RTD inputs, sensor short for RTD  input, below 1mA for 4-20mA input, below 0.25V for 1 – 5V input, not available for other inputs
Sensor Break Responding TimeWithin 4 seconds for Thermocouple and RTD inputs, 0.1 seconds for 4-20mA and 1 – 5V inputs

Input

Digital Input (DI1 or DI2)
No. of Event Inputs1
Logic Low-10V minimum, 0.8V maximum.
Logic High2V minimum, 10V maximum
FunctionsRefer to user manual

Output

Analog Retransmission Output 1 /Output 2 /Output 3
Number of Outputs3
Output Signal4-20mA, 0-20 mA,0 – 10VDC

Specification

Resolution15 Bits
Accuracy±0.05% of Span ± 0.0025% / °C
Load Resistance0 to 500Ω for current output, 10KΩ minimum for Voltage Output
Output Regulation0.01% for full load change
Output Setting Time0.1Second (stable to 99.9%)
Isolation Breakdown1000VAC min
Integral Linearity Error±0.005% of span
Temperature Effect±0.0025% of span /°C
Saturation Low0mA or 0VDC
Saturation High22.2mA or 5.55V,11.1V min
Linear Output Ranges0 – 22.2mA (0 – 20mA/4 – 20mA), 0 – 5.55VDC (0 – 5VDC, 1 – 5VDC),0 – 11.1VDC (0 – 10VDC)

Communication

Data Communication
InterfaceRS-485
ProtocolModbus RTU (Slave Mode)
Address1 to 247
Baud RateLatching, Hold, Normal, Latching/Hold
Dwell Timer0.1 to 4553.6 Minutes
Data Communication
InterfaceRS-485
ProtocolModbus RTU (Slave Mode)
Address1 to 247
Baudrate2.8KBPS to 115.2 KBPS
Parity BitNone, Even or Odd
Stop Bit1 or 2 Bits
Data  Length7 or 8 Bits
Communication Buffer160 Bytes
User Interface
Keypad4 Keys
Display Type4 Digit LCD Display
No of Display2
Upper Display Size0.58” (15mm)
Lower Display Size0.3” (7.8mm)
User Interface
Keypad4 Keys
Display Type4 Digit LCD Display
No. of Display2
Upper Display Size0.31”(8mm)
Lower Display Size0.25”(6.5mm)
Programming Port
InterfaceMicro USB
PC Communication FunctionFirmware upgrade
Digital Filter
FunctionFirst Order
Time Constant0,0.2, 0.5, 1, 2, 5, 10, 20, 30, 60 Seconds, Programmable
Environmental and Physical Specifications
Operating Temperature-10°C to 50°C
Storage Temperature-40°C to 60°C
Humidity0 to 90 % RH (Non-Condensing)
Altitude2000 Meters maximum
PollutionDegree II
Insulation Resistance20MΩ minimum(@500V DC)
Dielectric Strength2000V AC,50/60 Hz for 1 Minute
Vibration Resistance10 to 55 Hz , 10m/s2 for 2 Hours
Shock Resistance200 m/s2(20g)
Dimensions (W*H*D) (mm)22.5*96*83
Weight (grams)160
Approval Standards
SafetyUL61010-1, CSA 22.2 No.61010-1-12, EN61010-1 (IEC1010-1)
Protective ClassIP66 for Panel, IP20 for terminals and housing, all indoor use
EMCEN61326

For further information please contact : marketing@wmablog.com

Diterbitkan oleh Rudy Wiratama

rudywinoto.com/wmablog.com/flowmasonic.com

Tinggalkan Balasan

Please log in using one of these methods to post your comment:

Logo WordPress.com

You are commenting using your WordPress.com account. Logout /  Ubah )

Gambar Twitter

You are commenting using your Twitter account. Logout /  Ubah )

Foto Facebook

You are commenting using your Facebook account. Logout /  Ubah )

Connecting to %s

This site uses Akismet to reduce spam. Learn how your comment data is processed.